Call 0794256029529% Response Rate
Send E-mail

Handheld Pulse Oximeter

Our range of products include intex handheld pulse oximeter.
Get CALLBACK

Intex Handheld Pulse Oximeter

Intex Handheld Pulse Oximeter
 
Get Best Quote
Approx. Rs 400 / Piece
Get Latest Price

Product Details:
Minimum Order Quantity50 Piece
BrandIntex
FeaturesDigital
Measurement accuracy1BPM or + 1% of the Measured Value (take the larger value)
Automatic shutdownAutomatically shutdown after 8 seconds without finger insertion
Warranty2 Years
Battery model2 AAA 1.5V alkaline batteries;
Environmental Temperature5 DegreeC ~ 40 DegreeC
Pulse rate30BPM-240BPM
Model numberIT-OX02
Storage Temperature-10 DegreeC ~ 40 DegreeC
Atmospheric pressure70kPa -106kPa
Model nameOxiSure
Display modeLCD Two Color Display
Power consumptionLess Than 30mA
Country of OriginMade in India

The Intex Handheld Pulse Oximeter produced by our company is a kind of noninvasive and continuous medical instrument for detecting the arterial oxygen saturation and pulse rate of human body. It is portable and can accurately and rapidly measure the blood oxygen, so that you know whether you are lack of oxygen at present.

Product Feature
  • The product adopts two-color LCD display, and the interface can display six different display modes;
  • The power consumption of the product is low, and the two AAA batteries can last for more than 40 hours;
  • There is a low voltage warning in dication when the battery vdtage is too low, which may affect normal use;
  • When no signal is generated, the product will enter standby mode after 8 seconds
  • Small size, light weight, easy to carry.

Other Details
  • High Reading Accuracy
  • Stability Against Motion
  • 4 Direction Display Mode
  • Low Oxygen Alert

Safety Requirements
  • Not shared with MRI or CT equipment
  • Explosion hazard: do not use this instrument in the environment of flammable anesthetic gas.
  • Blood oxygen instrument only plays an auxiliary role in the diagnosis of the patient, ask the doctor to make a diagnosis based on the clinical manifestations and symptoms.
  • The oximeter sensor test site should be checked frequently to confirm that the skin of the patient at the sensor test site is intact and circulatory.
  • The fingertip pulse oximeter sensor is not suitable for contact with the adhesive tape, which may result in incorrect measurements or mistaken skin blisters.
  • Please read this manual carefully before use.
  • Blood oxygen meter has no function of blood oxygen indication, but it can not be used as a continuous monitor for a long time.
  • When using for a long time, please change the test point periodically according to the different situation of the patient. The test point must be replaced and the skin integrity, circulation and correct adjustment must be made every 2 hours at most
  • High pressure disinfection, vinyl oxide disinfectant, or immersion of sensors in liquid disinfectant can cause false readings.
  • Disorders of important indicators of hemoglobin, such as carboxyhemoglobin or methemoglobin, can cause incorrect readings.
  • Excessive intravascular staining, such as indocyanine green or methylene blue, can cause incorrect readings.
  • The measurement accuracy of blood oxygen saturation will be affected by the bright light of the surrounding environment.
  • (e.g, disinfection wipes or direct sunlight) add a protective case to the sensor if necessary.
  • The patient’s unexpected movements can cause false readings.
  • Interference with a medical high frequency signal or defibrillator can cause false readings.
  • The rhythmic beating of the veins can cause false readings.
  • The sensor’s position in the same artery or blood vessel as the blood pressure cuff can cause a false reading Patients with low blood pressure, severe low systolic blood pressure, severe anemia, or hypothermia can cause false readings
  • Taking a cardiac stimulant after a patient’s heart has stopped beating or if the patient is shaking can cause a false reading
  • Bright nails or nail polish coated nails cause erroneous readings.

Declaration: before using this product for testing, please use medical alcohol to wipe the rubber of finger sleeve first, and use medical alcohol to wipe the tested finger before and after using. (the rubber material is medical rubber, which is non-toxic, harmless and has no side effects such as allergy to human skin.)